產(chǎn)品簡介
product
產(chǎn)品分類TSS sc probes can measure both online suspended solids and turbidity in one instrument. They cover the total measurement range from the finest turbidity to solids over a wide range. TSS sc probes have been specially developed for industrial applications in production processes in the chemical and pharmaceutical sector and for the requirements of industrial wastewater plants. Connects directly to all Hach sc controllers for immediate use. TriClamp model provides simple inline installation and quick access for maintenance.
TSS sc probes have a double optical system with two pulsating infrared LEDs and four receivers. This combined multiple beam alternating light method with beam focusing facilitates accurate color independent measurement of turbidity from 0.001 to 4.000 FNU and suspended solids from 0.001 to 500 g/l.
Special software enables the system to recognize gas bubbles or temperature swings for a more accurate suspended solids or turbidity measurement.
The turbidity measurement complies with the standard DIN EN 27027 (ISO 7027). Calibration is not necessary. If the probe is used to measure the solids content, a one-point calibration suffices. For special applications, curves can be defined using several calibration points.
Probes are made of highly polished stainless steel with a scratch resistant sapphire window. They are design to withstand harsh environments and keep particles from sticking to the surface.
Turbidity & Suspended Solids sensor, user manual
Accuracy:FNU/NTU: 5 % of measured value ±0.01 FNU/NTU
Ambient Temperature:0 to 60 °C TSS sc, TSS TITANIUM2 sc, TSS TITANIUM7 sc
Calibration:Trubidity (TRB): Factory calibrated Solids (TS): To be calibrated by customer on site Zero point: Permanently calibrated in the factory
Dimensions (D x L):1.57 in x 13.07 in (40 mm x 332 mm)
Measurement Method:Combined multiple beam alternating light method with infrared diode system and beam focusing Turbidity (TRB): 2-channel 90º scattered light measurement in accordance with DIN/EN 27027/ISO 7027, wavelength = 60 nm Solids (TS): 90º and 120º scattered light measurement, wavelength = 60 nm
Pressure Limit:< 6 bar : TSS W sc
Response Time:1 s < T90 < 300 s (adjustable)
Weight:Tank sensor, inline sensor (TriClamp): Approx. 3.53 lbs. (1.6 kg)